Advanced Search
Server Technology CX-24VYI311 24xC13 Pdu
We apologize but this item is currently unavailable. Please feel free to browse our website for other available items.
Enlarge
Item Code:
PDUSTCX24VYI311
Manufacturer:
Model:
CX-24VYI311 Q7F05A
Item Condition Description:
Please note, this unit is new and includes 1x Walther CEE 5-prong power cable with sleeve, Buttons KIT-0020, and 1x Phone Line Cable.
Item Description

Server Technology CX-24VYI311 Master 208V 24x IEC 60320/C13 1x NEMA 5-20R Current Display Switched Cabinet Distribution Unit PDU. The Server Technology Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet.

Model Number:
CX-24VYI311
Walther Cable Part Number: 230-509
Compatible Part Numbers: Q7F05A







Features:

The Server Technology Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched “Master” PDU can be connected to a Switched “Link” PDU to extend the network access to the redundant or secondary power feed.

Network Monitoring
Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Auto-Flip Current Display
Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high density cabinets. "Switched"

Outlet Control
On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.

Color Identification
Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

Temperature/Humidity Monitoring
Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.

Branch Circuit Protection
This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

Includes:

- Buttons (KIT-0020) included for tool-less mounting
- 1x Phone Line Cable
- 1x 14ft CEE 32A 230V Walther 5-prong weather-resistant power cable with sleeve 230-509











Specifications:

Inputs
- Input Voltage (V): 120/208 ~ 50/60Hz
- Input Current (A): 30
- Input Current Rated: 24A
- Input Power Capacity (kW): 8.6
Outputs
- 24x C13 = 12A
- 1x 5-20R = 16A each
- Connector Rating: (24) x IEC 60320/C13, (1) x NEMA 5-20R (Utility) North American Rating: = 16A @120V L-N(20A Peak)

Physical
- Dimensions: 69.0in tall x 1.75in wide x 2.25in deep [1753mmx 45mmx 58mm]

Branch Circuit Protection
- (6) 20A Fuses, three (3) branch with tool-less retraction, meets UL 60950-1 requirements (Bussmann SC-20 fuses), 100 kA Interrupt Rating

Environmental
Operating Environment:
32°F to 122°F / 0°C to 50°C | 8%RH to 90%RH non-condensing | 6,500ft/2k melevation
Storage Environment:
-40°F to 185°F / -40°C to 85°C | 8%RHto 90%RH non-condensing | 50,000ft/15km elevation Quiescent/ Unloaded Power Draw: < 10W for all configurations

Communications & Security
- 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
- Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
- Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6,
- LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Input Measurement Accuracy:
- LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
- GUICurrent = ± 5% at 0.01 amp resolution (above 0.25 amp)