Server Technology 208V 24xC13 Switch Pdu
We apologize but this item is currently unavailable. Please feel free to browse our website for other available items.
Enlarge
Item Code:
CDUSRTCSEV4103V
Manufacturer:
Model:
SEV-4103V CX24VT-DFLA58AC
Item Condition Description:
This unit is new and includes a 1x 10ft CS-8365C Power Cord, 24x C13 Retaining Clips, 2x Mounting Button Kits, and a 1x 14ft AT614 Modular Line Cord.
Item Description

Server Technology CX24VT-DFLA58AC 208V 3-Phase 50/60A 24x IEC320 C13 PIPS Expansion Sentry Switched Cabinet Power Distribution Unit SEV-4103V. The Server Technology Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet.

Server Technology Part Number:
SEV-4103V
Model Number:
CX24VT-DFLA58AC











Features:

The integral PIPS technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched “Master”PDU can be connected to a Switched “Link”PDU to extend the network access to the redundant or secondary power feed.

Network Monitoring

Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.

Auto-Flip Current Display
Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high density cabinets. "Switched".

Branch Circuit Protection
This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

High Temperature Rating
This product has been tested and approved for safe and reliable operation in 60 °C data center environments.

Color Identification
Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

Temperature/Humidity Monitoring
Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.

Per- Inlet Power Sensing
Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.

Outlet Control
On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.

Flexible Mounting
Includes standard button mounts along with provisions for custom mounting brackets.

Includes:


- 1x 10ft (3m) CS-8365C 3p-4W 250V Hubbell Power Cord
- 24x C13 Cable Retaining Clips (1U wide, KIT-0030)
- KIT-MBVPT-1B Rack Mounting Bracket Kit
- 2x KIT-0020 Mounting Button Kit
- 1x Allen AT614 14ft Full Modular Line Cord











Specifications:

Inputs
- Input Voltage (V): 208
- Input Plug: CS8365 3P+G 50A
- Input Current (A): 50
- Input Current Rated (A): 40
- Input Power Capacity (kW): 14.4

Outputs
- (24) x IEC 60320/C13 North American Rating: ≤ 12A @208V L-L (15A Peak)

Branch Circuit Protection
- UL489 Compliant 2-pole, 20A trip circuit breakers, six (6) branch, rating: ≤ 16A, 5 kAIC Interrupt Rating

Physical
- Dimensions: 70.0in tall x 1.75in wide x 3.5in deep [1778mmx 45mmx 89mm]

Environmental
- Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RHnon-condensing | 6,500ft/2km elevation
- Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RHnon-condensing | 50,000ft/15km elevation
- Quiescent/ Unloaded Power Draw: < 10W for all configurations

Communications & Security
- 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector)
- Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU}
- Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6,
- LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP

Certifications
North American:
- cTUVus Mark to UL 60950-1:2007 R10.14
- CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014
- FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A

Measurement Accuracy
Input Measurement Accuracy
- LED Current = ± 10% at 0.1 amp (0.5 - 9.9 amps) and 1 amp (> 9.9 amps) resolution
- GUI Current = ± 1% at 0.01 amp resolution (above 0.5 amp)
- Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%)
- Active Power = ± 1% at 1 watt resolution
- Apparent Power = ± 1% at 1 volt-amp resolution
- Power Factor = ± 3% at 0.01 resolution
- Crest Factor = ± 10% at 0.1 resolution
- Energy = ± 1% at 0.1 kilowatt-hour resolution